Before 2015 the code required that reroofs must meet all the requirements of chapter 15 which would include the provisions of section 1503 4 which requires a secondary drainage system or scuppers.
Window above roof ibc.
Fall protection requirements state that windows with openings more than 72 above the finished grade or surface below are to have a minimum sill height of 24 above the interior finished floor.
Window headers support the roof and other structure above a window.
Minimum window sill heights the 2015 ibc contains requirements for minimum sill heights for operable windows in apartments townhouses duplexes and single family homes.
If you choose a header that is too small its weakness could lead to a collapse.
The 2012 ibc and 2012 irc require the bottom of openings created by operable windows to be a minimum height above the adjacent interior floor when they are more than 6 feet above the grade outside the window.
Section 1015 requires the bottom of openings created by these windows to be a minimum of 36 inches above the adjacent interior floor when they are 72 inches or more above grade.
Tempered glass must be used if the window has the bottom edge which is 18 inches above the floor and the top edge over 26 inches above the floor.
In the 2012 ibc the required height of that window sill above the adjacent interior floor is 36 inches.
Opening of the window shall be a minimum of 24 inches 610 mm above the finished floor of the room in which the windowis located.
Operable sections of windows shall not permit openings that allow passage of a 4 inch 102 mm diameter sphere where such openings are located within 24.
The international building code ibc dictates the sizes of headers to ensure that they.
In cases where the sill height is less than 24 the window shall not have an opening greater than would allow for a 4 diameter sphere to pass.
According to the 2018 irc all windows that are more than 6 feet above the grade outside the window must have a bottom opening a minimum of 24 inches above the room s interior floor.
The ibc allows non classified roof coverings to be used on residential group r 3 see ibc section 310 5 and group u see ibc section 312 buildings such as agricultural buildings barns carports if the separation between the leading edges of the adjacent roofs is less than 6 feet unless otherwise required by local requirements such as the.
Exception 2 was added to the 2015 edition of the ibc.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Exceptions can be made for windows that do not open more than 4 inches or that have window guards or opening control devices in compliance with astm f2090 17.